Main trade-off
AprilAire E080
Its published airflow falls more sharply under duct resistance. Check the actual pressure rather than assuming collar size proves compatibility.
Head-to-head
Choose E100 when an installer confirms that the moisture load or duct resistance calls for its higher capacity and stronger fan curve. At 0.2 inches of static pressure, E100 delivers 245 CFM against E080’s 135. Both have the same 14 by 26 by 15 inch body and ten-inch collars. E080 remains a reasonable choice when its capacity and pressure capability satisfy the design and its current total installed price is preferable. Neither includes a pump or solves inlet conditions below the manual’s operating limits.
Before you choose
At zero external static pressure, the published airflow is 185 CFM for E080 and 280 for E100. At 0.2 inches water column it is 135 and 245. That means the longer or more restrictive duct route in a finished home can change the practical value of the upgrade. A qualified installer should calculate the actual resistance before choosing. The numbers support a fan-performance distinction, not a claim that E100 removes a particular amount more water through your ducts.
What this is based on
Manufacturer fan curve at matched pressure points crossed with an existing duct route. Maximum design static is 0.4 for E080 and 0.6 for E100. Airflow is not converted to extraction.
Main trade-off
Its published airflow falls more sharply under duct resistance. Check the actual pressure rather than assuming collar size proves compatibility.
Main trade-off
Higher capacity does not remove drain, temperature or filter-access requirements. There is no onboard pump.


AprilAire E080 vs E100 for an existing duct system, basement or attic installation. Compare fan performance, service space and the limits of extra capacity.
These adjacent AprilAire installation models share cabinet dimensions and duct collar size. The practical question is whether the installation needs E100 capacity and fan performance.
Winner by situation
E100 retains more airflow at the published matched pressure points.
Extra E100 capability may be unused. Compare the actual installed total.
Both share the documented lower operating limits.
Both require 15 inches on one side for filter withdrawal. Matching body dimensions do not remove that space.
What matters in practice
At zero external static pressure, the published airflow is 185 CFM for E080 and 280 for E100. At 0.2 inches water column it is 135 and 245. That means the longer or more restrictive duct route in a finished home can change the practical value of the upgrade. A qualified installer should calculate the actual resistance before choosing. The numbers support a fan-performance distinction, not a claim that E100 removes a particular amount more water through your ducts.
Manufacturer fan curve at matched pressure points crossed with an existing duct route. Maximum design static is 0.4 for E080 and 0.6 for E100. Airflow is not converted to extraction.
Both bodies measure 14 inches wide, 26 deep and 15 high, so E100 does not need a larger bare opening than E080. Both also need 15 inches on one side to withdraw the filter. A unit that can be slid into place but cannot be serviced will create a repeated access problem. Before using the matching dimensions to justify an upgrade, check the filter path, drain and collar connections with the surrounding storage or framing in place.
Equal cabinet dimensions crossed with the shared 15-inch filter withdrawal requirement. Installation fit is separated from transport fit.
Both manuals specify 50 to 104 F inlet air and at least a 40 F dew point. If the intended space falls below those conditions, buying E100 for its larger rating does not remove that shared limit. Likewise, both require a suitable gravity drain or a separate pump when water must rise. An installer may need to change the placement or drainage before either capacity makes sense. This is particularly important when comparing a warm-room rating with a cool, lightly heated crawlspace.
Shared inlet and drainage conditions crossed with a cold installation and elevated disposal point. No prediction below the operating envelope.

AprilAire, E080 standalone, E080Z package code, no separate controller or pump assumed
The verified load and duct calculation fit E080, and its current total installed price is preferable.

AprilAire, E100 standalone, E100Z package code, no casters or separate controller assumed
The design needs the stronger published fan curve or higher rated moisture capacity.
Meaningful differences
| What changes | AprilAire E080 | AprilAire E100 | Why it matters |
|---|---|---|---|
| Rated moisture removal | 80 pints at 80 F and 60% RH, zero external static | 100 pints under the same conditions | A 25% rating increase is not a 25% faster home-drying promise. |
| Airflow at 0.2 in. water column | 135 CFM | 245 CFM | E100 preserves more fan airflow through a resistive installation. |
| Airflow at 0.4 in. water column | 85 CFM | 210 CFM | These fan points are not extraction ratings at those pressures. |
| Body and duct collars | 14 W × 26 D × 15 H inches, ten-inch collars | Same dimensions and ten-inch collars | Body size does not force a larger opening, but service and installation still need checking. |
| Inlet conditions | 50 to 104 F, minimum 40 F dew point | Same limits | Extra capacity does not make E100 a cold-space workaround. |
What you give up
What matters in practice
You want more moisture control without rebuilding the installation, but a larger daily rating cannot fix every duct or temperature problem.
What the facts say
Useful conclusions from the current dehumidifiers comparison, followed by the checked facts used to reach them.
| Product | Needs matched | Checked facts | Source records |
|---|---|---|---|
| AprilAire E080 |
|
| |
| AprilAire E100 |
|
|
Ready to choose?
Open either model on Amazon to check the current price, customer reviews and delivery options.

The verified load and duct calculation fit E080, and its current total installed price is preferable.
You have no installation requirement that uses E100’s additional capacity or fan capability.
See price & reviews on Amazon
The design needs the stronger published fan curve or higher rated moisture capacity.
The same cabinet dimensions and collar size are useful when upgrading an installation.
See price & reviews on AmazonLinks open in a new tab.