Main trade-off
Santa Fe Ultra70
Trap elevation can consume the apparent low-height advantage. It also uses replaceable filter media.
Head-to-head
Choose Ultra70 when its narrower body and eight-inch connections suit an installer-approved system. Ultra70’s 12-inch body needs six inches above the secondary drain pan for its trap, so do not treat its lower cabinet as lower installed height automatically. Choose E080 when its 80-pint rating, ten-inch duct route and washable filter fit the job. E080 does not require an external drain trap. Both need a suitable drain and service access.
Before you choose
Ultra70 is three inches lower as a bare cabinet. Its current manual also raises the base six inches above the secondary drain pan to accommodate the P-trap. For a low attic or crawlspace, that can overturn a quick choice based on the 12-inch headline. E080’s body is 15 inches high and does not require an external trap, but still needs its instructed drain slope, pan protection and access. Compare complete drawings rather than subtracting the two cabinet heights.
What this is based on
Body height and Ultra70 trap-elevation instruction crossed with low-space installation. No universal minimum enclosure height claimed because other clearances and pan geometry apply.
Main trade-off
Trap elevation can consume the apparent low-height advantage. It also uses replaceable filter media.
Main trade-off
Its body is taller, wider and 8 lb heavier. The filter needs 15 inches of side withdrawal space.


Santa Fe Ultra70 4044100 vs AprilAire E080 for a low attic or crawlspace. Check the full drain-trap height, duct connections and recurring filter work.
Both support permanent ducted dehumidification. A homeowner seeking a low-profile installation can reasonably choose between Ultra70’s body shape and E080’s higher capacity and different drain arrangement.
Winner by situation
Ultra70 uses eight-inch collars and a 12-inch-wide cabinet.
E080 combines ten-inch collars with washable media.
Trap, drain, pan and service clearances still need checking.
Check the complete pan and drain design. Ultra70 specifically needs its base six inches above the secondary pan for the trap.
What matters in practice
Ultra70 is three inches lower as a bare cabinet. Its current manual also raises the base six inches above the secondary drain pan to accommodate the P-trap. For a low attic or crawlspace, that can overturn a quick choice based on the 12-inch headline. E080’s body is 15 inches high and does not require an external trap, but still needs its instructed drain slope, pan protection and access. Compare complete drawings rather than subtracting the two cabinet heights.
Body height and Ultra70 trap-elevation instruction crossed with low-space installation. No universal minimum enclosure height claimed because other clearances and pan geometry apply.
Ultra70 uses eight-inch collars, while E080 uses ten-inch collars. If the home already has a suitable eight-inch dedicated duct route, Ultra70 may avoid a connection-size change after an installer confirms resistance and airflow. E080 instead offers washable filter media, while Ultra70 requires replacement MERV13 media at its prescribed intervals. Someone paying for difficult attic access should consider both the initial duct work and the later filter routine. A nominal filter rating is not a health result.
Duct connection size and independent filter maintenance crossed with an existing system and difficult recurring access.
Both need appropriate protection when installed above finished space. Ultra70 specifies a secondary pan with a float switch, and E080’s manual also calls for drain-pan and float protection in that setting. That requirement can matter more than the ten-pint rating difference. If the buyer wants the unit out of sight in an attic, the quote should include protection and reachable service access. Neither a larger capacity nor a remote control replaces those safeguards.
Both manuals’ finished-space protection requirements crossed with an attic installation. No guarantee against leakage or property damage.

Santa Fe, Ultra70 exact current part 4044100 A2L
The eight-inch duct design and narrower cabinet fit your planned system.

AprilAire, E080 standalone, E080Z package code, no separate controller or pump assumed
The design needs the 80-pint class and accepts ten-inch collars.
Meaningful differences
| What changes | Santa Fe Ultra70 | AprilAire E080 | Why it matters |
|---|---|---|---|
| Matched removal rating | 70 pints at 80 F and 60% RH | 80 pints at 80 F and 60% RH | Rated capacity must fit the actual load. |
| Body dimensions | 12 W × 28 D × 12 H inches | 14 W × 26 D × 15 H inches | Ultra70 is lower and narrower, but two inches longer. |
| Duct collars | Eight inches | Ten inches | Existing duct size changes the work needed. |
| Drain and filter | External trap, replaceable MERV13 | No external trap, washable MERV8 | Installation and recurring care differ independently of capacity. |
What you give up
Recommendation switch
Choose Santa Fe Ultra70. Ultra70 matches that physical design.
Choose AprilAire E080. E080 fits those requirements.
What matters in practice
You want a low unit above or below living space without hiding a drain or service problem in the installation.
What the facts say
Useful conclusions from the current dehumidifiers comparison, followed by the checked facts used to reach them.
| Product | Needs matched | Checked facts | Source records |
|---|---|---|---|
| Santa Fe Ultra70 |
|
|
|
| AprilAire E080 |
|
|
Ready to choose?
Open either model on Amazon to check the current price, customer reviews and delivery options.

The eight-inch duct design and narrower cabinet fit your planned system.
The complete A2L installation, including raised trap arrangement and filter access, is verified.
See price & reviews on Amazon
The design needs the 80-pint class and accepts ten-inch collars.
A washable filter and no external trap make maintenance and drainage simpler.
See price & reviews on AmazonLinks open in a new tab.