The short answer

Choose E070 when its 70-pint rating meets the calculated load and the lower, lighter cabinet or eight-inch connections are important. Choose E100 when the design needs its 100-pint capacity and supports the larger cabinet and duct route. E100 adds 30 rated pints but needs ten-inch rather than eight-inch collars. Both share minimum inlet conditions, so the larger model is not a remedy for an installation that runs too cold.

Before you choose

The reasoning and the trade-offs

A large capacity jump can require a larger installation job

E100’s 100-pint rating is about 43% above E070’s 70 at the stated matched conditions. It also switches from eight-inch to ten-inch collars and adds 8 lb to a taller body. For an inaccessible crawlspace, those changes affect delivery, duct connections and later service. If E070 already meets the calculated load, the extra rating may be unused. If it does not, choose the larger capacity with the necessary installation work rather than choking it back into an unverified old duct path.

What this is based on

(100 - 70) / 70 is about 43%, a capacity-rating comparison only. Collar, height and weight changes crossed with replacement access.

Main trade-off

AprilAire E070 Pro

The lower matched-condition removal rating may be insufficient for a genuinely larger load.

Main trade-off

AprilAire E100

Its body is 2.5 inches taller and 8 lb heavier. Larger connections and service space can complicate replacement.

AprilAire E070 Pro

AprilAire E070 Pro

Choose it for
  • The verified load fits 70 pints and the access route favors a 12.5-inch-high, 56 lb unit.
  • An appropriate eight-inch installation is worth preserving.
Main trade-off
The lower matched-condition removal rating may be insufficient for a genuinely larger load.
See price & reviews on Amazon
AprilAire E100

AprilAire E100

Choose it for
  • The calculated load requires the 100-pint class and the duct design meets its pressure requirements.
  • You can provide ten-inch connections and sufficient filter and drain access.
Main trade-off
Its body is 2.5 inches taller and 8 lb heavier. Larger connections and service space can complicate replacement.
See price & reviews on Amazon

Analysis updated , Catalog updated , Amazon.com / United States

About this comparison

AprilAire E070 vs E100 for a constrained crawlspace or a larger ducted job. Compare access, existing ducts and why a bigger rating cannot fix cold inlet air.

A buyer sizing a permanent AprilAire installation may be tempted to jump from E070 to E100 for headroom. The useful question is whether that headroom matches the building and installation.

Winner by situation

Start with what you need it to do

  • Adequate 70-pint sizing and difficult delivery access

    E070 is lower, narrower and 8 lb lighter.

    AprilAire E070 Pro
    Better fit
    AprilAire E100
    Caution
  • The design calls for 100-pint capacity and ten-inch ducts

    E100 supplies the higher matched-condition rating.

    AprilAire E070 Pro
    Caution
    AprilAire E100
    Better fit
  • Conditions below the specified inlet limits

    Both share the lower operating boundary.

    AprilAire E070 Pro
    Not suitable
    AprilAire E100
    Not suitable
  • The disposal point is above the installed unit

    Both need a separate suitable pump. A higher daily removal rating does not change water routing.

    AprilAire E070 Pro
    Caution
    AprilAire E100
    Caution

What matters in practice

The differences that matter

A large capacity jump can require a larger installation job

E100’s 100-pint rating is about 43% above E070’s 70 at the stated matched conditions. It also switches from eight-inch to ten-inch collars and adds 8 lb to a taller body. For an inaccessible crawlspace, those changes affect delivery, duct connections and later service. If E070 already meets the calculated load, the extra rating may be unused. If it does not, choose the larger capacity with the necessary installation work rather than choking it back into an unverified old duct path.

How we reached this conclusion

(100 - 70) / 70 is about 43%, a capacity-rating comparison only. Collar, height and weight changes crossed with replacement access.

Winter conditions can erase the reason for buying the larger label

Both manuals set a 50 F minimum inlet temperature and 40 F minimum dew point for dehumidification. A cool crawlspace can therefore present a placement or operating-envelope problem that E100’s bigger warm-condition rating does not solve. Check the seasonal conditions where air enters the unit. The same caution applies to drainage. Neither has an onboard pump, so a higher disposal point still needs a separate solution. Capacity, temperature and water routing must all fit at once.

How we reached this conclusion

Shared inlet limits and no-pump drainage crossed with seasonal cold and an elevated disposal point. No claim about performance outside the published conditions.

The service path can be larger than the cabinet difference

E100 needs 15 inches on one side for filter withdrawal. A buyer may find room for the 14-inch-wide cabinet and still block the exact movement needed for cleaning. E070’s smaller body does not waive its own access instructions either. Before deciding that either unit fits, sketch where the filter comes out and where a person can reach the drain. This is especially important when the appliance sits behind storage that will be put back after installation.

How we reached this conclusion

Documented E100 filter withdrawal crossed with real use of storage and permanent placement. E070 clearance is not guessed or declared smaller.

Choice A
AprilAire E070 Pro

AprilAire, E070

E070 Pro

The verified load fits 70 pints and the access route favors a 12.5-inch-high, 56 lb unit.

Best matched use
The verified load fits 70 pints and the access route favors a 12.5-inch-high, 56 lb unit.

Checked facts

  • Matched capacity: 70 pints at 80 F and 60% RH
  • Body height and weight: 12.5 inches, 56 lb
  • Duct connection: Eight-inch collars
  • Cold inlet boundary: 50 F minimum and 40 F minimum dew point
Choice B
AprilAire E100

AprilAire, E100 standalone, E100Z package code, no casters or separate controller assumed

E100

The calculated load requires the 100-pint class and the duct design meets its pressure requirements.

Best matched use
The calculated load requires the 100-pint class and the duct design meets its pressure requirements.

Checked facts

  • Matched capacity: 100 pints at 80 F and 60% RH
  • Body height and weight: 15 inches, 64 lb
  • Duct connection: Ten-inch collars
  • Cold inlet boundary: Same limits

Meaningful differences

What changes the fit

Meaningful differences between AprilAire E070 Pro and AprilAire E100
What changesAprilAire E070 ProAprilAire E100Why it matters
Matched capacity70 pints at 80 F and 60% RH100 pints at 80 F and 60% RHThe 30-pint difference does not establish a household drying-time ratio.
Body height and weight12.5 inches, 56 lb15 inches, 64 lbE070 leaves more transport and placement margin.
Duct connectionEight-inch collarsTen-inch collarsReusing a small duct route requires checking, not just an adapter.
Cold inlet boundary50 F minimum and 40 F minimum dew pointSame limitsBigger capacity does not remove the shared lower boundary.

What you give up

Every choice has a cost

If you choose AprilAire E070 Pro

  • Existing duct compatibility still needs confirmation. Eight-inch collars alone are not a whole-system design.

If you choose AprilAire E100

  • The drain hose, any separate pump and optional controls must be included in the installed total.

Recommendation switch

The decision flips if...

70-pint sizing is sufficient and access is the harder problem

Choose AprilAire E070 Pro. E070 has the smaller, lighter body.

Verified moisture load needs the larger unit and its installation fits

Choose AprilAire E100. E100 provides the higher capacity.

What matters in practice

Before you choose

You want enough capacity for the difficult season without overcomplicating an already awkward crawlspace installation.

Check these before buying

  • Size from moisture load and inlet conditions, not floor area alone.
  • Check the delivery route and filter withdrawal space.
  • Include duct changes and drainage in the installed quote.

What this comparison cannot tell you

  • No exact capacity threshold for a home is inferred from its size or occupants. Rating ratios are not speed or efficiency ratios.

What the facts say

What the comparison shows

Useful conclusions from the current dehumidifiers comparison, followed by the checked facts used to reach them.

See the checked facts and calculation notes
Compared set
2 models
Source records
5 for the products shown
Catalog updated
Facts and source records used for the products in this recommendation
ProductNeeds matchedChecked factsSource records
AprilAire E070 Pro
  • The verified load fits 70 pints and the access route favors a 12.5-inch-high, 56 lb unit.
  • An appropriate eight-inch installation is worth preserving.
  • Matched capacity: 70 pints at 80 F and 60% RH
  • Body height and weight: 12.5 inches, 56 lb
  • Duct connection: Eight-inch collars
  • Cold inlet boundary: 50 F minimum and 40 F minimum dew point
AprilAire E100
  • The calculated load requires the 100-pint class and the duct design meets its pressure requirements.
  • You can provide ten-inch connections and sufficient filter and drain access.
  • Matched capacity: 100 pints at 80 F and 60% RH
  • Body height and weight: 15 inches, 64 lb
  • Duct connection: Ten-inch collars
  • Cold inlet boundary: Same limits

Ready to choose?

Check the price. Read the owner reviews.

Open either model on Amazon to check the current price, customer reviews and delivery options.

AprilAire E070 Pro

AprilAire E070 Pro

The verified load fits 70 pints and the access route favors a 12.5-inch-high, 56 lb unit.

An appropriate eight-inch installation is worth preserving.