Main trade-off
AprilAire E070 Pro
The lower matched-condition removal rating may be insufficient for a genuinely larger load.
Head-to-head
Choose E070 when its 70-pint rating meets the calculated load and the lower, lighter cabinet or eight-inch connections are important. Choose E100 when the design needs its 100-pint capacity and supports the larger cabinet and duct route. E100 adds 30 rated pints but needs ten-inch rather than eight-inch collars. Both share minimum inlet conditions, so the larger model is not a remedy for an installation that runs too cold.
Before you choose
E100’s 100-pint rating is about 43% above E070’s 70 at the stated matched conditions. It also switches from eight-inch to ten-inch collars and adds 8 lb to a taller body. For an inaccessible crawlspace, those changes affect delivery, duct connections and later service. If E070 already meets the calculated load, the extra rating may be unused. If it does not, choose the larger capacity with the necessary installation work rather than choking it back into an unverified old duct path.
What this is based on
(100 - 70) / 70 is about 43%, a capacity-rating comparison only. Collar, height and weight changes crossed with replacement access.
Main trade-off
The lower matched-condition removal rating may be insufficient for a genuinely larger load.
Main trade-off
Its body is 2.5 inches taller and 8 lb heavier. Larger connections and service space can complicate replacement.


AprilAire E070 vs E100 for a constrained crawlspace or a larger ducted job. Compare access, existing ducts and why a bigger rating cannot fix cold inlet air.
A buyer sizing a permanent AprilAire installation may be tempted to jump from E070 to E100 for headroom. The useful question is whether that headroom matches the building and installation.
Winner by situation
E070 is lower, narrower and 8 lb lighter.
E100 supplies the higher matched-condition rating.
Both share the lower operating boundary.
Both need a separate suitable pump. A higher daily removal rating does not change water routing.
What matters in practice
E100’s 100-pint rating is about 43% above E070’s 70 at the stated matched conditions. It also switches from eight-inch to ten-inch collars and adds 8 lb to a taller body. For an inaccessible crawlspace, those changes affect delivery, duct connections and later service. If E070 already meets the calculated load, the extra rating may be unused. If it does not, choose the larger capacity with the necessary installation work rather than choking it back into an unverified old duct path.
(100 - 70) / 70 is about 43%, a capacity-rating comparison only. Collar, height and weight changes crossed with replacement access.
Both manuals set a 50 F minimum inlet temperature and 40 F minimum dew point for dehumidification. A cool crawlspace can therefore present a placement or operating-envelope problem that E100’s bigger warm-condition rating does not solve. Check the seasonal conditions where air enters the unit. The same caution applies to drainage. Neither has an onboard pump, so a higher disposal point still needs a separate solution. Capacity, temperature and water routing must all fit at once.
Shared inlet limits and no-pump drainage crossed with seasonal cold and an elevated disposal point. No claim about performance outside the published conditions.
E100 needs 15 inches on one side for filter withdrawal. A buyer may find room for the 14-inch-wide cabinet and still block the exact movement needed for cleaning. E070’s smaller body does not waive its own access instructions either. Before deciding that either unit fits, sketch where the filter comes out and where a person can reach the drain. This is especially important when the appliance sits behind storage that will be put back after installation.
Documented E100 filter withdrawal crossed with real use of storage and permanent placement. E070 clearance is not guessed or declared smaller.

AprilAire, E070
The verified load fits 70 pints and the access route favors a 12.5-inch-high, 56 lb unit.

AprilAire, E100 standalone, E100Z package code, no casters or separate controller assumed
The calculated load requires the 100-pint class and the duct design meets its pressure requirements.
Meaningful differences
| What changes | AprilAire E070 Pro | AprilAire E100 | Why it matters |
|---|---|---|---|
| Matched capacity | 70 pints at 80 F and 60% RH | 100 pints at 80 F and 60% RH | The 30-pint difference does not establish a household drying-time ratio. |
| Body height and weight | 12.5 inches, 56 lb | 15 inches, 64 lb | E070 leaves more transport and placement margin. |
| Duct connection | Eight-inch collars | Ten-inch collars | Reusing a small duct route requires checking, not just an adapter. |
| Cold inlet boundary | 50 F minimum and 40 F minimum dew point | Same limits | Bigger capacity does not remove the shared lower boundary. |
What you give up
Recommendation switch
Choose AprilAire E070 Pro. E070 has the smaller, lighter body.
Choose AprilAire E100. E100 provides the higher capacity.
What matters in practice
You want enough capacity for the difficult season without overcomplicating an already awkward crawlspace installation.
What the facts say
Useful conclusions from the current dehumidifiers comparison, followed by the checked facts used to reach them.
| Product | Needs matched | Checked facts | Source records |
|---|---|---|---|
| AprilAire E070 Pro |
|
| |
| AprilAire E100 |
|
|
Ready to choose?
Open either model on Amazon to check the current price, customer reviews and delivery options.

The verified load fits 70 pints and the access route favors a 12.5-inch-high, 56 lb unit.
An appropriate eight-inch installation is worth preserving.
See price & reviews on Amazon
The calculated load requires the 100-pint class and the duct design meets its pressure requirements.
You can provide ten-inch connections and sufficient filter and drain access.
See price & reviews on AmazonLinks open in a new tab.